ECRA Licence #7018049
347/600V Systems

600V Electrician in Toronto

Portman Electric installs and troubleshoots 347/600V commercial electrical systems in Toronto — 347V lighting circuits, 600V distribution, disconnects, motor and equipment supplies and the transformers that step it down to 120/208V.

  • Building operators
  • Facility managers
  • General contractors
  • Property managers
Call 647-835-7757
Electrical distribution and control cabinets in an equipment room

Need commercial service?

647-835-7757

Emergency calls answered 24/7.

ECRA/ESA Licence #7018049
Licensed & insured
ESA notification handled where required
Service calls + project work
When to call Portman

Call Us If…

Real situations, not a capabilities list. If one of these sounds familiar, you're in the right place.

  1. 01347V corridor, warehouse or parking lighting is out across a zone.
  2. 02A 600V disconnect or panel is hot, noisy or damaged.
  3. 03Equipment fed at 600V has lost a phase or won't start.
  4. 04A renovation needs 600V feeders or panels altered.
  5. 05A transformer-fed 120/208V panel has gone dead.
The system

How 347/600V Commercial Power Is Used

At 347/600V, a building can run lighting at 347V phase-to-neutral and large equipment at 600V three-phase, with smaller feeders and less voltage drop over long runs. Receptacles and small equipment are then fed at 120/208V through step-down transformers. Faults and alterations can sit on either side of those transformers, so a 600V electrician has to understand the whole chain.

Electrical distribution and control cabinets in an equipment room
Installation

347/600V Installation Work

  • 600V distribution panels, feeders and disconnects
  • 347V lighting circuits and fixtures
  • 600V three-phase equipment and motor supplies
  • Step-down transformers to 120/208V panels
  • Alterations for renovations and tenant changes
Troubleshooting

600V Troubleshooting

Common 600V and 347V faults include failed lighting ballasts and drivers on 347V circuits, lost phases at fuses or breaker poles, heat-damaged terminations at disconnects, and transformer primary or secondary failures. We isolate the faulted section, test it, and explain the repair before proceeding.

Switchgear cabinets and protective controls in an electrical room
Safety

Higher Voltage, Careful Planning

Work on 347/600V equipment is planned with isolation and shutdown coordination. If you notice heat, noise, burning smells or arcing at 600V equipment, keep people clear and call — this is not equipment for anyone untrained to open.

347/600V Service or Project

  1. STEP 1

    Describe the equipment, symptoms or project scope.

  2. STEP 2

    Site review of panels, transformers and single-line information if available.

  3. STEP 3

    Diagnosis or a written quote with shutdown plan.

  4. STEP 4

    Isolation and work during the agreed window.

  5. STEP 5

    Testing and restoration.

  6. STEP 6

    Documentation and ESA inspection where required.

Safety first. If you see smoke or fire, or someone has been shocked, call 911 first. Do not open panels, reset repeatedly tripping breakers or work on live equipment yourself — keep people clear and call us. Urgent? Call 647-835-7757 or see commercial emergency service.

Request commercial service

Something Not Working? Book a Service Call.

Describe the problem, add photos if you have them, and tell us how urgent it is. For emergencies, call instead — forms are not monitored like the phone line.

Request commercial service

For urgent faults, call 647-835-7757. For smoke, fire or immediate danger, move away and call 911. Do not open energized equipment to take photos.

Request commercial service details

Planning a project instead?

Send drawings, specs and schedule through the project quote form.

Request a project quote